Issue 2/1994

Characteristics of air cleaning and air conditioning equipments (Part No. 3) PDF 36 MB

Abstract...

The paper deals with evaluation of function of 11 abroad made filtration apparatuses determinated for indoor air cleaness and IAQ improvement. Dust collection efficiencies of the apparatuses have been evaluated. Air f1-ws (air capacities), noise levels, ozone concentrations and Iight negative ions concentrations in the air have been investigated too.
ŠIMEČEK ,J. ,LAJČÍKOVÁ ,A., MATHAUSEROVÁ ,Z., JANDÁK,Z. ,2 - 4
Noise reduction (Part No.9) PDF 36 MB

Abstract...

-
NOVÝ,R. ,5 - 7
Air flow determination in the course of non-stationary ventllation PDF 36 MB

Abstract...

The method favourable to air flow determination from the balance equation of non-stationary ventilation is presented in the paper there. The method of the interative calculation is after modification of the basic equation demonstrated on the example of the circulation air fi/ter there. The paper completes the analysis of problems of in- time-variable ventilation which have been published in VVI3/93.
HEMZAL K.,8 - 9
The static system of cooling ceilings PDF 36 MB

Abstract...

-
DMST-TKT s.r.o.11 - 16
The low energy consumption house - demonstrative project PDF 36 MB

Abstract...

-
HAUSNER P.17 - 24
Ventilation of stables PDF 36 MB

Abstract...

Requirements and angles of view for choice of suitable venti/ation systems for stable of agriculture in the Czech Republic are discussed in the paper. Representative ways of na tura I and mechanical venti/ation systems suitable as for reconstructed stable bui/dings as for new ones are presented there. The systems consider energy savings need and the ways of venti/ating with the best environmental results for the shedding cattle are accented. Perspectives in the branch of technics of stable environment are discussed in the paper there.
KIC P.26 - 29
Radon and its daughters products measurement PDF 36 MB

Abstract...

Methods of average equivalent volume radon activity (radon daughters products) estimation and results of an application of one of the mostly used method (track detectors) are described in the paper. Measurement of the instantaneous values of this quantity (air sampling through a filter and filter activity measurement) is losing importance nowadays with regard to ascertained variability of values in the majority of the cases. The method of determination of the instantaneous value of the radon concentration by means of scintillation chambers is mentioned there with respect to its importance for determination of soil radon and radon in water. Causes of concentrations higher than average are commented together with the possibilities of their reduction there (although experience in this field is not extensive in the Czech Republic).
BURIAN I.30 - 33
Question of fuels of the current turbo-compressor cooling units PDF 36 MB

Abstract...

-
PETRÁK,J.,34 - 39
Capacity control of steam-water heat exchangers PDF 36 MB

Abstract...

Ways of capacity control of steam-water heat exchangers are described in the article, asset and drawback of their insta/lation in central heat supply systems are discussed there too. Experience with operation and control of the heat exchangers is presented there.
KRATOCHVÍL,P.41 - 43
Right installation of a heat meter in buildings PDF 36 MB

Abstract...

-
LOVÁS,J.50 - 50
Capillary indicators of heating costs PDF 36 MB

Abstract...

-
HLAVAČKA,V.52 - 53
Experience concerning authorization procedure under the Czech low 36-/93 Sb. PDF 36 MB

Abstract...

-
KOTRBATÝ,M.54 - 55
- PDF 36 MB

Abstract...

-
KUBÍČEK,L.57 - 61